This IV drip rate calculator gives the drops per minute and the pump rate in mL/h for any infusion. Enter the volume to infuse, the time in hours and minutes, and the drop factor printed on the giving set: 10, 15 or 20 gtt/mL for macro-drip sets or 60 gtt/mL for micro-drip. The result shows the exact and rounded drops per minute, the seconds between drops and how many drops to count in 15 seconds, so you can set a gravity line against a watch. A second panel works backwards from a pump rate to the infusion time. For a full shift, paste or drop a CSV of IV orders and every row is calculated at once, ready to download. It is free, works entirely in your browser, and no patient data ever leaves your device. It is a calculation aid only: always check the prescription, the set label and your facility's protocol.
| Order | mL/h | 10 gtt/mL | 15 gtt/mL | 20 gtt/mL | 60 gtt/mL |
|---|---|---|---|---|---|
| 1000 mL / 8 h | 125 | 21 | 31 | 42 | 125 |
| 1000 mL / 12 h | 83 | 14 | 21 | 28 | 83 |
| 500 mL / 4 h | 125 | 21 | 31 | 42 | 125 |
| 100 mL / 30 min | 200 | 33 | 50 | 67 | 200 |
| 250 mL / 6 h | 42 | 7 | 10 | 14 | 42 |
Drops per minute = volume in mL × drop factor in gtt/mL ÷ time in minutes.
Use the number printed on the giving set's packaging. Adult macro-drip sets are usually 10, 15 or 20 gtt/mL; micro-drip (paediatric) sets are 60 gtt/mL.
A micro-drip set gives 60 drops per mL and an hour has 60 minutes, so the two numbers cancel out.
Yes. You cannot count part of a drop, so round to the nearest whole drop; the exact figure is shown for reference.
No. All calculations run in your browser and nothing is uploaded.
The gravity drip rate is volume (mL) × drop factor (gtt/mL) ÷ infusion time (minutes), the standard nursing formula. The pump rate is volume ÷ time in hours (mL/h). Because a micro-drip set delivers 60 drops per mL, its gtt/min always equals mL/h. Drops per minute are shown exact and rounded to a whole drop, since drops cannot be split at the bedside, along with seconds per drop and drops in 15 seconds for counting against a watch. A second panel inverts the rate: minutes = volume ÷ mL/h × 60. In batch mode each IV order row is calculated independently and an invalid row is flagged without stopping the rest.