This AC tonnage calculator tells you what size air conditioner a room needs, in tons, BTU per hour and kW. Enter the room's length, width and ceiling height in feet or meters, how many people usually use it, how sunny it is and whether it is a kitchen, and it starts from the ENERGY STAR sizing chart and applies the chart's own adjustments, then scales for ceilings above 8 feet. Two optional switches add a margin for a top-floor room under the roof and for summers above 40 °C, which is common across Pakistan, India and the Gulf. The answer is rounded to the nearest standard unit, from 0.75 to 5 tons, with every step of the calculation shown. To plan a whole house, paste a CSV of rooms and each one is sized at once. It is free, runs in your browser, and your room details are never uploaded.
| Area (sq ft) | BTU/h | Tons |
|---|---|---|
| 100–150 | 5,000 | 0.42 |
| 150–250 | 6,000 | 0.5 |
| 250–300 | 7,000 | 0.58 |
| 300–350 | 8,000 | 0.67 |
| 400–450 | 10,000 | 0.83 |
| 450–550 | 12,000 | 1 |
| 550–700 | 14,000 | 1.17 |
| 700–1,000 | 18,000 | 1.5 |
| 1,400–1,500 | 24,000 | 2 |
Roughly 1 ton for 450–550 sq ft in the ENERGY STAR chart, but a sunny top-floor room in a 45 °C summer can need 1.5 tons for the same area. Enter your room to see the full adjustment.
One ton of cooling is 12,000 BTU per hour, or about 3.5 kW.
No. An oversized unit cools the air quickly and switches off before it removes humidity, leaving the room cold and clammy and wasting energy.
Yes. The chart assumes an 8 ft ceiling; a 10 ft ceiling has 25% more air to cool, so the load is scaled up.
No. All calculations run in your browser.
The base load is read from the ENERGY STAR room air conditioner sizing chart (5,000 BTU/h for 100–150 sq ft up to 34,000 BTU/h for 2,000–2,500 sq ft, extended at 20 BTU per sq ft beyond). ENERGY STAR's adjustments follow: −10% for a heavily shaded room, +10% for a very sunny one, +600 BTU/h for each regular occupant beyond two and +4,000 BTU/h for a kitchen. The chart assumes an 8 ft ceiling, so the load is scaled by height ÷ 8 for taller rooms. Two optional field rules of thumb add 15% each for a top-floor room under a sun-baked roof and for climates with summers above 40 °C. Tons = BTU/h ÷ 12,000 and kW = BTU/h × 0.29307; the suggested size is the nearest standard capacity (0.75 to 5 tons) at or above the load.