This PCB trace width calculator sizes copper traces to carry a current without overheating, using the IPC-2221 formula. Enter the current, the temperature rise you'll accept, the copper weight and whether the trace is on an outer or inner layer, and it gives the minimum width in mils and millimetres. Add the trace length to see its resistance, voltage drop and power loss. Paste every power net's current to size them all. It runs in your browser.
| Current | Outer, 1 oz | Inner, 1 oz | Outer, 2 oz |
|---|---|---|---|
| 0.5 A | 4.5 mil | 11.8 mil | 2.3 mil |
| 1 A | 11.8 mil | 30.8 mil | 5.9 mil |
| 2 A | 30.8 mil | 80.0 mil | 15.4 mil |
| 3 A | 53.8 mil | 140 mil | 26.9 mil |
| 5 A | 109 mil | 283 mil | 54.4 mil |
| 10 A | 283 mil | 737 mil | 142 mil |
About 12 mil (0.3 mm) on an outer layer with 1 oz copper and a 10 °C rise; about 31 mil on an inner layer.
Inner layers can't shed heat to air, so IPC-2221 halves the constant and they need about 2.6 times the area.
10 °C is a common, conservative choice; 20–30 °C is used where space is tight.
IPC-2152 uses newer measurements and often allows narrower traces; IPC-2221 remains the common conservative rule.
No. Everything runs in your browser.
IPC-2221 relates current to cross-section: I = k × ΔT^0.44 × A^0.725, where A is in square mils, ΔT the allowed temperature rise in °C, and k = 0.048 for external layers or 0.024 for internal layers. Solving for A and dividing by copper thickness (1 oz/ft² ≈ 1.378 mil, 35 µm) gives the width. Resistance of a trace of given length uses copper resistivity 1.72 × 10⁻⁸ Ω·m adjusted to the trace temperature (ambient + rise), giving voltage drop and power loss. Batch mode reads each net's current and layer.