This 555 timer calculator works out the output of the classic NE555 circuit. In astable mode enter R1, R2 and C to get the frequency, duty cycle and high and low times, or enter a target frequency to find R2. In monostable mode enter R and C for the pulse width. Values can be typed as 4.7k, 100n or 10µ. Paste a list of component combinations to compare them. It runs in your browser.
| R1 | R2 | C | Frequency | Duty |
|---|---|---|---|---|
| 1 kΩ | 10 kΩ | 10 µF | 6.87 Hz | 52.4% |
| 10 kΩ | 68 kΩ | 10 µF | 0.99 Hz | 53.4% |
| 1 kΩ | 6.8 kΩ | 100 nF | 988 Hz | 53.4% |
| 4.7 kΩ | 4.7 kΩ | 1 µF | 102 Hz | 66.7% |
| 1 kΩ | 1 kΩ | 10 nF | 48.1 kHz | 66.7% |
f = 1.44 ÷ ((R1 + 2R2) × C). With R1 = 1 kΩ, R2 = 10 kΩ and C = 10 µF it is about 6.9 Hz.
The high time includes R1, so it is always longer than the low time. Add a diode across R2 or use a CMOS 555 trick to get 50% or less.
t = 1.1 × R × C. 100 kΩ and 10 µF gives about 1.1 seconds.
Capacitor tolerance dominates; electrolytics can be ±20%, so use film capacitors for precise timing.
No. Everything runs in your browser.
Astable mode: the capacitor charges through R1 + R2 and discharges through R2, so high time = ln 2 × (R1 + R2) × C, low time = ln 2 × R2 × C, frequency = 1.44 ÷ ((R1 + 2R2) × C) and duty cycle = (R1 + R2) ÷ (R1 + 2R2). Monostable mode: pulse width = 1.1 × R × C. Given a target frequency, R1 and C, R2 = (1.44 ÷ (f × C) − R1) ÷ 2. Values accept engineering notation (4k7, 100n, 10µ). Batch mode reads R1, R2 and C per row; a blank R2 means monostable.