This ISO fits calculator gives the exact limits for a hole and shaft pair such as H7/g6. Enter the nominal size up to 500 mm and pick the hole and shaft zones — or one of the common fits from loose running to locational interference — and it shows each part's upper and lower limits in millimetres and microns, plus the minimum and maximum clearance or interference and whether it's a clearance, transition or interference fit. Paste every fit from a drawing to check them all. It runs in your browser.
| Fit | Hole µm | Shaft µm | Range µm | Type |
|---|---|---|---|---|
| H9/d9 | 0/+52 | −117/−65 | 65 to 169 | Clearance |
| H8/f7 | 0/+33 | −41/−20 | 20 to 74 | Clearance |
| H7/g6 | 0/+21 | −20/−7 | 7 to 41 | Clearance |
| H7/h6 | 0/+21 | −13/0 | 0 to 34 | Clearance |
| H7/k6 | 0/+21 | +2/+15 | −15 to 19 | Transition |
| H7/n6 | 0/+21 | +15/+28 | −28 to 6 | Transition |
| H7/p6 | 0/+21 | +22/+35 | −35 to −1 | Interference |
Hole 25.000–25.021 mm, shaft 24.980–24.993 mm: a sliding clearance fit of 7 to 41 µm.
H7/p6 is the usual locational interference fit; at 50 mm it gives 1 to 42 µm interference.
The hole's lower limit is the nominal size; its tolerance goes upward by the IT grade.
One that can end up with slight clearance or slight interference, such as H7/k6.
No. Everything runs in your browser.
Limits follow ISO 286 for nominal sizes up to 500 mm. The tolerance grade width comes from the standard IT5–IT11 values for the size range. Shafts d, e, f, g and h have an upper deviation es from the fundamental deviation table and lower = es − IT; shafts k, m, n and p have a lower deviation ei and upper = ei + IT (k is zero outside IT4–IT7); js is ±IT/2. Holes H, G, F, E and D mirror the shaft deviations (EI = −es) and JS is ±IT/2. Maximum clearance = hole upper − shaft lower; minimum = hole lower − shaft upper; the fit is clearance, transition or interference accordingly.