Pipe Flow and Pressure Drop Calculator

This pipe pressure drop calculator works out how much pressure a pipe loses for a given flow, using the Darcy–Weisbach equation with the Colebrook friction factor. Enter the inside diameter, length, flow and pipe material, plus any fittings and height change, and it shows the pressure drop in kPa, bar, psi and metres of head, the velocity, Reynolds number and friction factor, and how much comes from friction, fittings and elevation. Change density and viscosity for other liquids. Paste every segment of a system to size a pump. It runs in your browser.

Water at 20 °C in steel pipe, per 100 m

Inside ØFlowVelocityPressure drop
15.8 mm0.2 L/s1.02 m/s105.9 kPa
26.6 mm0.5 L/s0.90 m/s43.2 kPa
40.9 mm1.5 L/s1.14 m/s39.0 kPa
52.5 mm2.5 L/s1.15 m/s29.2 kPa
77.9 mm6 L/s1.26 m/s21.0 kPa
102.3 mm10 L/s1.22 m/s14.1 kPa

When to use it

  1. Size a pipe for a water supply line.
  2. Find the head a pump must overcome.
  3. Check velocity against noise and erosion limits.
  4. Compare steel and plastic pipe.
  5. Work through every segment of a system.

How to Use

  1. Enter inside diameter, length and flow.
  2. Choose the pipe material.
  3. Add fittings ΣK and any rise.
  4. Read pressure drop, velocity and Reynolds number; paste segments.

Features

  1. Darcy–Weisbach with Colebrook
  2. Roughness presets
  3. Fittings and elevation
  4. Any liquid
  5. kPa, bar, psi and head
  6. Batch CSV
  7. 100% client-side

FAQs

How do I calculate pressure drop in a pipe?

ΔP = f × (L/D) × ρv²/2, with f from the Colebrook equation.

What velocity should water have?

About 1–3 m/s in most systems; higher gets noisy and erodes fittings.

What is the K value of a fitting?

A loss coefficient: a 90° elbow is about 0.3–0.9, an open gate valve about 0.2 and a globe valve about 10.

Can I use it for oil or glycol?

Yes. Enter the fluid's density and viscosity.

Is anything uploaded?

No. Everything runs in your browser.

Technical Details

Velocity v = flow ÷ (π/4 × D²) and Reynolds number Re = ρvD/μ. The Darcy friction factor is 64/Re for laminar flow and otherwise solved from the Colebrook–White equation 1/√f = −2 log10(ε/3.7D + 2.51/(Re√f)) by iteration. Pressure drop ΔP = f × (L/D) × ρv²/2 for the pipe, plus ΣK × ρv²/2 for fittings and ρgΔz for elevation. Roughness presets cover steel, galvanised and cast iron, plastics, copper and concrete. Batch mode reads one pipe segment per row.

Calculators & Converters

Calculators & Converters

  • Psychrometric Calculator
  • Pump Power and Head Calculator
  • Heat Exchanger LMTD Calculator
  • Welding Heat Input Calculator
  • Weld Metal and Electrode Estimator
  • Coordinate Converter (Lat/Long, UTM, DMS)
  • Plot Area from Coordinates Calculator
  • Bearing and Distance Calculator