This solar system sizer tells you how many kW of solar panels, how many panels, what inverter and how big a battery bank you need, starting from the units on your electricity bill. Enter your monthly units or daily kWh, the peak sun hours where you live and the panel wattage you plan to buy, and it accounts for real-world losses through a performance ratio, rounds up to whole panels and shows the roof space they take. Add the energy you want stored for the night or for outages and it sizes a lithium or lead-acid bank in kWh and in Ah at 12, 24 or 48 V. Expected output is shown per day, month and year so you can check it against your bill. To compare quotes for small, medium and large systems, paste a CSV of options and every one is sized side by side. It is free, works entirely in your browser, and nothing you enter is uploaded.
| Units per month | kW needed | Panels | Installed kW | Roof space (m²) |
|---|---|---|---|---|
| 300 | 2.33 | 5 | 2.75 | 13 |
| 500 | 3.89 | 8 | 4.40 | 21 |
| 600 | 4.66 | 9 | 4.95 | 23 |
| 900 | 6.99 | 13 | 7.15 | 34 |
| 1,200 | 9.32 | 17 | 9.35 | 44 |
Divide your daily kWh by peak sun hours × about 0.78 for losses to get kW, then divide by the panel wattage. 600 units a month at 5.5 sun hours needs about 4.7 kW, or nine 550 W panels.
The number of hours per day the sun would need to shine at 1,000 W/m² to deliver the day's total energy. Pakistan and most of India average about 5 to 6 hours a year.
At least 1.25 times the largest load you run at once, and not much smaller than the panel array; most homes end up with an inverter close to the array size.
Take the kWh you want to use from storage and divide by depth of discharge and efficiency: about 0.85 for lithium and 0.43 for lead-acid. 5 kWh of night use needs about 5.9 kWh of lithium.
No. Everything is calculated in your browser.
Daily energy is taken directly or as monthly bill units ÷ 30. The array size is daily kWh ÷ (peak sun hours × performance ratio), where the performance ratio (75–80% typical) covers heat, dust, mismatch, wiring and inverter losses; it is rounded up to whole panels of the chosen rating. Expected output is installed kWp × sun hours × performance ratio, per day, month (×30) and year (×365). The inverter is the next standard size above the larger of peak load × 1.25 and installed kWp ÷ 1.25, a common DC-to-AC ratio ceiling. For hybrid or off-grid systems the battery bank is energy to store ÷ (depth of discharge × round-trip efficiency): 90% and 95% for LiFePO4, 50% and 85% for lead-acid, then converted to Ah at the bank voltage. Roof space is panel count × panel area.